{
  "notice": "bxzxxr MCP archive: a record of what public MCP servers declared when we listed them (we never call their tools). It is data, not a rating: nothing here says a server is safe, secure, verified or trustworthy, and a server can change after we looked. Secrets we detected are redacted; redacted tool lists are withheld and only their hash is shown.",
  "infrastructure": {
    "host": "thecablecode.com",
    "site": "thecablecode.com",
    "addresses": [
      {
        "address": "104.21.69.220",
        "endpoints": 1,
        "shared_infrastructure": false,
        "network": {
          "asn": 13335,
          "name": "CLOUDFLARENET - Cloudflare, Inc.",
          "prefix": "104.21.64.0/19",
          "country": "US"
        }
      },
      {
        "address": "172.67.213.130",
        "endpoints": 1,
        "shared_infrastructure": false,
        "network": {
          "asn": 13335,
          "name": "CLOUDFLARENET - Cloudflare, Inc.",
          "prefix": "172.67.208.0/20",
          "country": "US"
        }
      },
      {
        "address": "2606:4700:3037::6815:45dc",
        "endpoints": 1,
        "shared_infrastructure": false,
        "network": {
          "asn": 13335,
          "name": "CLOUDFLARENET - Cloudflare, Inc.",
          "prefix": "2606:4700:3037::/48",
          "country": "US"
        }
      },
      {
        "address": "2606:4700:3032::ac43:d582",
        "endpoints": 1,
        "shared_infrastructure": false,
        "network": {
          "asn": 13335,
          "name": "CLOUDFLARENET - Cloudflare, Inc.",
          "prefix": "2606:4700:3032::/48",
          "country": "US"
        }
      }
    ],
    "addresses_recorded": true,
    "address_history": [
      {
        "addresses": [
          "104.21.69.220",
          "172.67.213.130",
          "2606:4700:3037::6815:45dc",
          "2606:4700:3032::ac43:d582"
        ],
        "first_seen": "2026-11-21T15:28:02.865Z",
        "last_seen": "2026-11-21T15:28:02.865Z",
        "checks": 1
      }
    ],
    "hosting": [
      {
        "value": "Cloudflare",
        "evidence": "Server header \"cloudflare\""
      }
    ],
    "software": [],
    "server_info": {
      "name": "thecablecode",
      "version": "1.102.0",
      "protocol_version": "2025-06-18"
    },
    "headers": {
      "server": "cloudflare",
      "strict-transport-security": "max-age=31536000",
      "access-control-allow-origin": "*"
    },
    "auth": null
  },
  "related": {
    "same_address": {
      "total": 0,
      "sample": []
    },
    "same_site": {
      "total": 0,
      "sample": []
    },
    "same_tool_list": {
      "total": 0,
      "sample": []
    },
    "same_publisher": {
      "publisher": "io.github.exquad",
      "total": 0,
      "sample": []
    },
    "same_repository": null,
    "note": "Shared addresses on big platforms (Cloudflare, Vercel and the like) put unrelated servers together; those are marked shared_infrastructure. A match is a pivot, not a link between operators."
  },
  "endpoint": {
    "id": "29479",
    "server_name": "io.github.exquad/thecablecode",
    "url": "https://thecablecode.com/mcp",
    "host": "thecablecode.com",
    "transport": "streamable-http",
    "last_checked_at": "2026-11-21T15:28:02.865Z",
    "last_state": "listed",
    "last_detail": null,
    "consecutive_failures": 0,
    "current_sha": "13369ddc094fb1d0aace14beefbaec6ac5adde9b7c70694a82624092aebce022",
    "first_listed_at": "2026-11-21T15:28:02.865Z",
    "created_at": "2026-11-21T09:40:10.476Z",
    "resolved_addresses": [
      "104.21.69.220",
      "172.67.213.130",
      "2606:4700:3037::6815:45dc",
      "2606:4700:3032::ac43:d582"
    ]
  },
  "server": {
    "name": "io.github.exquad/thecablecode",
    "title": "The Cable Code",
    "description": "Decode cables in 71 coding systems; design, rate, check, find equivalents; drums, laying, fire.",
    "version": "1.101.0",
    "registry_status": "active",
    "repository_url": null,
    "website_url": "https://thecablecode.com/developers",
    "published_at": "2026-11-13T08:52:18.701Z",
    "updated_at": "2026-11-13T08:52:18.701Z",
    "first_seen": "2026-11-21T09:40:10.041Z"
  },
  "other_endpoints": [],
  "intel": {
    "capabilities": [
      "x402"
    ],
    "evm_addresses": [],
    "chains": [],
    "tokens": [
      "USDC"
    ],
    "computed_at": "2026-11-22T15:33:10.015Z"
  },
  "operator": null,
  "needs_sign_in": false,
  "reachability": {
    "window_days": 30,
    "checks": 1,
    "answered": 1,
    "answered_percent": 100,
    "avg_listing_latency_ms": 770,
    "first_check_in_window": "2026-11-21T15:28:02.865Z",
    "consecutive_failures_now": 0,
    "days": [
      {
        "day": "2026-11-21",
        "checks": 1,
        "answered": 1,
        "last_state": "listed"
      }
    ]
  },
  "tool_list": {
    "sha256": "13369ddc094fb1d0aace14beefbaec6ac5adde9b7c70694a82624092aebce022",
    "tools": 25,
    "resources": 40,
    "prompts": 0,
    "first_seen": "2026-11-21T15:28:03.637Z",
    "tool_names": [
      "decode_cable_code",
      "design_cable",
      "find_equivalents",
      "overhead_conductor",
      "check_cable",
      "extract_datasheet",
      "read_tender",
      "write_specification",
      "design_presets",
      "drum_fit",
      "burial_depth",
      "fire_class",
      "awg_metric",
      "conduit_fill",
      "pull_cable",
      "tray_fill",
      "drum_loading",
      "cold_weather_check",
      "mv_electrical",
      "economic_size",
      "commissioning_sheet",
      "cable_prep",
      "iec60287_rating",
      "degassing_time",
      "equivalence_report"
    ],
    "declared": {
      "tools": [
        {
          "name": "decode_cable_code",
          "title": "Decode a cable designation",
          "description": "Decode a cable type designation (DIN VDE, HAR, BS/IEC, NEC, TS, UTE, CEI-UNEL and 64 more of its 71 coding systems, plus LAN and fibre) into its layers: conductor, insulation, screen, armour, sheath, with the source behind each symbol. Deterministic, no LLM. 5 free calls per caller per UTC day (with find_equivalents, overhead_conductor), then $0.10 USDC per call (x402).",
          "inputSchema": {
            "type": "object",
            "$schema": "http://json-schema.org/draft-07/schema#",
            "required": [
              "code"
            ],
            "properties": {
              "code": {
                "type": "string",
                "examples": [
                  "NYY-J 3x1,5",
                  "N2XSEYRY",
                  "12/2 NM-B",
                  "H07RN-F 3G2,5"
                ],
                "maxLength": 120,
                "minLength": 1,
                "description": "A cable type designation as printed or listed."
              },
              "lang": {
                "enum": [
                  "en",
                  "tr",
                  "de",
                  "nl",
                  "sv",
                  "fr",
                  "es",
                  "da",
                  "no",
                  "fi",
                  "it",
                  "ro",
                  "pl",
                  "cs",
                  "ru"
                ],
                "type": "string",
                "description": "Any of the site's 15 languages; default en."
              }
            }
          },
          "annotations": {
            "readOnlyHint": true,
            "openWorldHint": false
          }
        },
        {
          "name": "design_cable",
          "title": "Design and size a power cable",
          "description": "Design and size a cable (power, control, LAN, coaxial, fibre) from a sentence in any site language, a designation, a spec or a design: each layer with its standard and source, diameter, weight, designation, current, voltage drop and short-circuit ratings, optional files (XML, DXF, SVG, CSV, GLB, STEP, PDF). Deterministic, no LLM; nominal values. Notes: thecablecode://guide/design_cable. 2 free designs per caller per UTC day, then $0.50 USDC per design (x402).",
          "inputSchema": {
            "type": "object",
            "$schema": "http://json-schema.org/draft-07/schema#",
            "properties": {
              "cpc": {
                "type": "object",
                "description": "The protective conductor check: {kind, system, device and device_a or ia_a, length_m, ...}.",
                "propertyNames": {
                  "type": "string"
                },
                "additionalProperties": {}
              },
              "nec": {
                "type": "object",
                "description": "North American wires: {ocpd_a, install, ambient_c, carrying, termination_c}: NEC ampacity and EGC; CSA designs by C22.1.",
                "propertyNames": {
                  "type": "string"
                },
                "additionalProperties": {}
              },
              "lang": {
                "enum": [
                  "en",
                  "tr",
                  "de",
                  "nl",
                  "sv",
                  "fr",
                  "es",
                  "da",
                  "no",
                  "fi",
                  "it",
                  "ro",
                  "pl",
                  "cs",
                  "ru"
                ],
                "type": "string",
                "description": "Language of the answer's words; the sentence is read in any."
              },
              "load": {
                "type": "object",
                "description": "For voltage_drop and sizing: {length_m (required), amps or kw, phases, volts, pf, limit_pct, conduit, formation}.",
                "propertyNames": {
                  "type": "string"
                },
                "additionalProperties": {}
              },
              "spec": {
                "type": "object",
                "description": "Or {voltage: \"12/20\", cores: 3, section: 95, metal, screen, insulation, sheath, armour, standard (a design_presets id), ...} or {lan: {category, shield, awg}}.",
                "propertyNames": {
                  "type": "string"
                },
                "additionalProperties": {}
              },
              "fault": {
                "type": "object",
                "description": "For cpc: {ka, seconds}, the adiabatic check up to 1 kV.",
                "propertyNames": {
                  "type": "string"
                },
                "additionalProperties": {}
              },
              "design": {
                "type": "object",
                "description": "Instead of a sentence: the design field of an earlier answer, changed.",
                "propertyNames": {
                  "type": "string"
                },
                "additionalProperties": {}
              },
              "fault_s": {
                "type": "number",
                "maximum": 5,
                "minimum": 0.1,
                "description": "Fault duration for ratings.short_circuit, s (default 1)."
              },
              "formats": {
                "type": "array",
                "items": {
                  "enum": [
                    "xml",
                    "dxf",
                    "svg",
                    "csv",
                    "glb",
                    "step",
                    "pdf"
                  ],
                  "type": "string"
                },
                "description": "Files to include: xml, dxf, svg, csv, glb, step, pdf (datasheet)."
              },
              "sentence": {
                "type": "string",
                "examples": [
                  "NA2XS(F)2Y 1x240/25 12/20 kV",
                  "3-core collective screen 12/20 kV 3x95/25 Al, longitudinally watertight",
                  "NYY-J 4x16"
                ],
                "maxLength": 300,
                "minLength": 1,
                "description": "The cable in words (any site language) or a designation; what is not said takes a default, listed in the answer."
              },
              "installation": {
                "type": "object",
                "properties": {
                  "air_c": {
                    "type": "number",
                    "description": "Air temperature, °C."
                  },
                  "group": {
                    "type": "integer",
                    "maximum": 12,
                    "minimum": 1,
                    "description": "Cables or circuits side by side."
                  },
                  "phase": {
                    "enum": [
                      "single",
                      "three"
                    ],
                    "type": "string",
                    "description": "IS 694 single-core: the circuit."
                  },
                  "tiers": {
                    "enum": [
                      "yes",
                      "no"
                    ],
                    "type": "string",
                    "description": "rating_basis is3961: buried in tiers."
                  },
                  "trays": {
                    "type": "integer",
                    "maximum": 3,
                    "minimum": 1,
                    "description": "Trays one above the other."
                  },
                  "h3_pct": {
                    "type": "number",
                    "description": "0.6/1 kV 4- and 5-core: third-harmonic share, %."
                  },
                  "is_pvc": {
                    "enum": [
                      "A",
                      "C"
                    ],
                    "type": "string",
                    "description": "rating_basis is3961, IS 1554-1: the PVC grade."
                  },
                  "laying": {
                    "enum": [
                      "buried",
                      "duct",
                      "air"
                    ],
                    "type": "string",
                    "description": "Buried, in a duct, or in air."
                  },
                  "loaded": {
                    "anyOf": [
                      {
                        "type": "number",
                        "const": 2
                      },
                      {
                        "type": "number",
                        "const": 3
                      }
                    ],
                    "description": "0.6/1 kV single-core: loaded conductors."
                  },
                  "method": {
                    "enum": [
                      "C",
                      "E",
                      "D_direct",
                      "D_duct"
                    ],
                    "type": "string",
                    "description": "BS 7671 reference method."
                  },
                  "depth_m": {
                    "type": "number",
                    "description": "Laying depth, m."
                  },
                  "support": {
                    "enum": [
                      "tray",
                      "ladder",
                      "vertical"
                    ],
                    "type": "string",
                    "description": "In air with a group: the support."
                  },
                  "ground_c": {
                    "type": "number",
                    "description": "Ground temperature, °C."
                  },
                  "strip_mm": {
                    "type": "number",
                    "description": "Short circuit: armour strip thickness, mm."
                  },
                  "au_method": {
                    "enum": [
                      "air",
                      "spaced",
                      "trefoil",
                      "conduit",
                      "buried",
                      "duct"
                    ],
                    "type": "string",
                    "description": "rating_basis au: the installation."
                  },
                  "clearance": {
                    "enum": [
                      "touching",
                      "oneDiameter",
                      "0.125",
                      "0.25",
                      "0.5",
                      "1.0"
                    ],
                    "type": "string",
                    "description": "0.6/1 kV: touching, oneDiameter, or a ground clearance, m."
                  },
                  "formation": {
                    "enum": [
                      "trefoil",
                      "flatTouching",
                      "flatSpaced"
                    ],
                    "type": "string",
                    "description": "Single-core circuits."
                  },
                  "is_method": {
                    "enum": [
                      "clipped",
                      "enclosed",
                      "defined",
                      "trefoil"
                    ],
                    "type": "string",
                    "description": "IS 694: the installation method."
                  },
                  "mv_temp_c": {
                    "anyOf": [
                      {
                        "type": "number",
                        "const": 90
                      },
                      {
                        "type": "number",
                        "const": 105
                      }
                    ],
                    "description": "Type MV and URD: the 90 or 105 °C column."
                  },
                  "reel_drum": {
                    "enum": [
                      "cylindrical",
                      "radial-vent",
                      "radial-closed"
                    ],
                    "type": "string",
                    "description": "A flexible cable on a reeling drum."
                  },
                  "iec_method": {
                    "enum": [
                      "A1",
                      "A2",
                      "B1",
                      "B2",
                      "C",
                      "D1",
                      "D2",
                      "E",
                      "F",
                      "G"
                    ],
                    "type": "string",
                    "description": "IEC 60364-5-52 reference method, 0.6/1 kV."
                  },
                  "is_circuit": {
                    "enum": [
                      "three",
                      "single",
                      "dc"
                    ],
                    "type": "string",
                    "description": "rating_basis is3961: the circuit."
                  },
                  "lead_alloy": {
                    "enum": [
                      "yes",
                      "no"
                    ],
                    "type": "string",
                    "description": "Short circuit: the lead sheath is a lead alloy."
                  },
                  "mv_install": {
                    "enum": [
                      "airIsolated",
                      "airTriplexed",
                      "conduitAir",
                      "duct",
                      "buried",
                      "buriedTriplexed"
                    ],
                    "type": "string",
                    "description": "Type MV and URD, NEC 315.60: the installation."
                  },
                  "protection": {
                    "enum": [
                      "close",
                      "coarse"
                    ],
                    "type": "string",
                    "description": "IS 694: the excess current protection."
                  },
                  "restrained": {
                    "enum": [
                      "yes",
                      "no"
                    ],
                    "type": "string",
                    "description": "Short circuit: buried, clamped or bent tight."
                  },
                  "spacing_mm": {
                    "type": "number",
                    "description": "Group spacing, mm; 0 touching."
                  },
                  "arrangement": {
                    "enum": [
                      "bunched",
                      "wall",
                      "ceiling",
                      "perforated",
                      "vertical",
                      "unperforated",
                      "ladder",
                      "spaced"
                    ],
                    "type": "string",
                    "description": "0.6/1 kV in air: how the group lies."
                  },
                  "circuit_use": {
                    "enum": [
                      "power",
                      "signal",
                      "electronic"
                    ],
                    "type": "string",
                    "description": "0.6/1 kV, Table 52.2: sets the smallest conductor."
                  },
                  "reel_layers": {
                    "type": "integer",
                    "maximum": 5,
                    "minimum": 1,
                    "description": "With reel_drum cylindrical: layers wound."
                  },
                  "loaded_cores": {
                    "type": "integer",
                    "maximum": 61,
                    "minimum": 1,
                    "description": "HD 603, over four cores: loaded cores."
                  },
                  "rating_basis": {
                    "enum": [
                      "iec",
                      "is3961",
                      "hd620",
                      "de",
                      "au"
                    ],
                    "type": "string",
                    "description": "The rating tables; default iec."
                  },
                  "air_formation": {
                    "enum": [
                      "trefoil",
                      "flat",
                      "horizontal",
                      "vertical"
                    ],
                    "type": "string",
                    "description": "0.6/1 kV single-core in free air."
                  },
                  "cord_carrying": {
                    "anyOf": [
                      {
                        "type": "number",
                        "const": 2
                      },
                      {
                        "type": "number",
                        "const": 3
                      }
                    ],
                    "description": "North American cord: current-carrying conductors."
                  },
                  "soil_k_m_per_w": {
                    "type": "number",
                    "description": "Soil thermal resistivity, K·m/W."
                  }
                },
                "description": "For ratings.current: how the cable is installed; what is not given takes the defaults the answer lists."
              },
              "test_variant": {
                "type": "string",
                "description": "A national variant of the tests after installation; default the design standard's."
              }
            }
          },
          "annotations": {
            "readOnlyHint": true,
            "openWorldHint": false
          }
        },
        {
          "name": "find_equivalents",
          "title": "Find a cable's equivalents in other countries",
          "description": "The same power cable under other countries' standards (IEC 60502, HD 603, HD 620, BS, EN 50618, HD 627), rebuilt and compared layer by layer with sources: equivalent, close (the differences) or none (the reason). Deterministic, no LLM; never a statement of interchangeability. Notes: thecablecode://guide/find_equivalents. The decodes' 5 free calls per caller per UTC day, then $0.10 USDC per call (x402).",
          "inputSchema": {
            "type": "object",
            "$schema": "http://json-schema.org/draft-07/schema#",
            "properties": {
              "code": {
                "type": "string",
                "examples": [
                  "AXCLJ-TT 3x95/25 12/20 kV",
                  "NA2XS(F)2Y 1x240/25 12/20 kV",
                  "NYY-J 4x16"
                ],
                "maxLength": 120,
                "minLength": 1,
                "description": "A power cable designation with its size and voltage."
              },
              "lang": {
                "enum": [
                  "en",
                  "tr",
                  "de",
                  "nl",
                  "sv",
                  "fr",
                  "es",
                  "da",
                  "no",
                  "fi",
                  "it",
                  "ro",
                  "pl",
                  "cs",
                  "ru"
                ],
                "type": "string",
                "description": "Language of the notes; default en."
              },
              "design": {
                "type": "object",
                "description": "Instead of code: a design (the design field of a design_cable answer), compared with its own layers.",
                "propertyNames": {
                  "type": "string"
                },
                "additionalProperties": {}
              },
              "country": {
                "type": "string",
                "examples": [
                  "NL",
                  "DE,GB"
                ],
                "description": "Comma separated target countries: NL, SE, DK, NO, DE, GB, INT, EU, ES, IT, FR, PT, IN, CN, JP, AU, ZA, TH, US, CA. Default: all."
              },
              "standard": {
                "type": "string",
                "description": "Comma separated target standards, e.g. HD620-10J, BS6724, IEC, EN50618; default all. Every id: thecablecode://guide/find_equivalents."
              }
            }
          },
          "annotations": {
            "readOnlyHint": true,
            "openWorldHint": false
          }
        },
        {
          "name": "overhead_conductor",
          "title": "Look up a bare overhead line conductor (EN 50182, ACSS)",
          "description": "A bare overhead line conductor (AAC, AAAC, ACSR, ACSS) by its code (\"242-AL1/39-ST1A\", EN 50182; \"401-AL0/28-MEHST\", FprEN 50540) or an EN 50182 Annex F table (\"F.19\"): stranding, areas, diameters, mass, strength and resistance as printed, with table and page. Deterministic, no LLM. Notes: thecablecode://guide/overhead_conductor. The decodes' 5 free calls per caller per UTC day, then $0.10 USDC per call (x402).",
          "inputSchema": {
            "type": "object",
            "$schema": "http://json-schema.org/draft-07/schema#",
            "properties": {
              "row": {
                "type": "string",
                "maxLength": 120,
                "description": "With table: one conductor code of that table."
              },
              "code": {
                "type": "string",
                "maxLength": 120,
                "minLength": 1,
                "description": "A bare overhead conductor code: EN 50182:2001 4.5, the envelope's area and wire then the core's, e.g. \"242-AL1/39-ST1A\", \"65-A20SA\", \"434-AL1/56-ST1A\"; or an ACSS code by FprEN 50540 clause 4, e.g. \"401-AL0/28-MEHST\", read by its areas. Every Annex F country table that lists it answers."
              },
              "core": {
                "enum": [
                  "ST6A",
                  "EHST",
                  "MEHST",
                  "UHST",
                  "MUHST",
                  "20SA",
                  "20EHSA",
                  "14EHSA"
                ],
                "type": "string",
                "description": "The core wire of the ACSS build (FprEN 50540 clause 4): ST6A, EHST, MEHST, UHST, MUHST, 20SA, 20EHSA, 14EHSA; default ST6A, or an ACSS code's own core."
              },
              "table": {
                "type": "string",
                "description": "Instead of code (or to narrow it): an EN 50182 Annex F country table (52 tables). Alone it answers every row of the table."
              }
            }
          },
          "annotations": {
            "readOnlyHint": true,
            "openWorldHint": false
          }
        },
        {
          "name": "check_cable",
          "title": "Check a power cable against a standard",
          "description": "Check a power cable (a designation with size and voltage, a design, or a datasheet's construction) against a standard's nominal rules: each rule with required, found, pass / fail / not checkable and its source. Deterministic, no LLM; not a certificate or a type test. Notes: thecablecode://guide/check_cable. 2 free checks per caller per UTC day, then $0.50 USDC per check (x402).",
          "inputSchema": {
            "type": "object",
            "$schema": "http://json-schema.org/draft-07/schema#",
            "properties": {
              "design": {
                "type": "object",
                "description": "Instead of a designation: a thecablecode design v1 (the design field of a design_cable answer).",
                "propertyNames": {
                  "type": "string"
                },
                "additionalProperties": {}
              },
              "standard": {
                "type": "string",
                "description": "\"auto\" (default: the standards the input claims) or rule sets, comma separated, at most 4: iec-60502-1-2004, iec-60502-2-2014, iec-60228-2023, hd-603-3-g, hd-603-5-g, hd-620-10-j, hd-620-10-m, hd-620-10-d, hd-620-10-c, hd-620-10-k, hd-620-10-e1, hd-620-10-e2, hd-620-10-i1, hd-620-10-i2, hd-620-10-i3, hd-620-10-g, hd-620-10-l, hd-620-10-n, hd-620-10-o, hd-620-10-p, hd-620-9-e, hd-620-9-i, hd-620-11-n, hd-620-11-o, hd-620-12-i, hd-620-12-j, hd-620-12-k, bs-5467, bs-6724, bs-7846, bs-6622, is-694, is-1554-1, is-1554-2, is-7098-1, is-7098-2, is-8130-2013, iec-62067-2011, iec-60840-2011, din-vde-0250-204, din-vde-0250-214, din-vde-0250-215, din-vde-0250-405, en-50525-2-31, en-50525-3-31, en-50525-2-11, en-50525-3-11, en-50525-2-21, en-50525-3-21, en-50525-2-51, en-50525-2-12, en-50525-2-41, en-50525-2-42, en-50525-2-72, en-50525-2-81, en-50525-2-82, en-50525-2-83, en-50525-3-41, en-50618-2014, iec-62930-cdv, din-vde-0271, gb-9330-2020, hd-627-4-n, hd-627-7-n, bs-7211-2012, as-nzs-5000-2-2006, ul-62-spt, din-vde-0815, din-vde-0250-502, din-vde-0250-602, din-vde-0250-806, din-vde-0250-812, din-vde-0250-814, sans-1507-4-2022, as-nzs-5000-3-2003, ul-1277, ul-13-2025, ul-1424-2025, ul-444-2026, aeic-cs9-06, jb-t-8735-2-2016, din-vde-0250-813, din-vde-0250-809, bs-6004-2012, gb-t-18890-2. Printed names work too (\"IEC 60502-2\", \"HD 620 10-J\")."
              },
              "designation": {
                "type": "string",
                "examples": [
                  "NA2XS(F)2Y 1x240/25 12/20 kV",
                  "NYY-J 4x16",
                  "H07RN-F 3G2.5"
                ],
                "maxLength": 120,
                "minLength": 1,
                "description": "A power cable designation with its size and voltage."
              },
              "construction": {
                "type": "object",
                "description": "Or a datasheet's construction: {voltage: \"12/20\", cores, conductor: {metal, section}, core: [{kind, material, nominal, minimum}], common: [...], standards}, inside out.",
                "propertyNames": {
                  "type": "string"
                },
                "additionalProperties": {}
              }
            }
          },
          "annotations": {
            "readOnlyHint": true,
            "openWorldHint": false
          }
        },
        {
          "name": "extract_datasheet",
          "title": "Read a cable datasheet into constructions",
          "description": "Read a power cable datasheet (an https link to a PDF or page, or pasted text) into constructions: each size's voltage, cores, conductor, layers with nominal and smallest thickness, screen, armour, diameters and standards, with page and row. An LLM (Claude) reads, deciding nothing; with standard set the rules check each row. Notes: thecablecode://guide/extract_datasheet. Price (USDC, x402): a paid call from the first document: $2.00 in USDC per document, no free allowance.",
          "inputSchema": {
            "type": "object",
            "$schema": "http://json-schema.org/draft-07/schema#",
            "properties": {
              "url": {
                "type": "string",
                "maxLength": 2000,
                "description": "An https link to a PDF datasheet or a datasheet web page."
              },
              "hint": {
                "type": "string",
                "maxLength": 120,
                "description": "A designation or size to look for, e.g. \"3x95/25 12/20 kV\": only matching rows are returned."
              },
              "text": {
                "type": "string",
                "maxLength": 60000,
                "description": "Pasted datasheet, catalogue or tender text."
              },
              "standard": {
                "type": "string",
                "description": "Also check every row: \"auto\" (the standards each row claims, else IEC 60502 by voltage) or rule sets, comma separated."
              }
            }
          },
          "annotations": {
            "readOnlyHint": true,
            "openWorldHint": true
          }
        },
        {
          "name": "read_tender",
          "title": "Read a tender document: cables built, requirements, schedule, conflicts and gaps",
          "description": "Read a tender or project document's text into its cables (built and checked by the rules), the required / offered schedule, requirements, conflicts and missing sections, with pages. An LLM (Claude) copies values, deciding nothing. Waits up to about two minutes, then answers a poll link (GET /api/v1/tender/{job}); a PDF: POST /api/v1/tender. Notes: thecablecode://guide/read_tender. Always paid: $4.00 up to 20 pages, $2.00 for each further 10 pages begun, up to 80 pages, USDC (x402).",
          "inputSchema": {
            "type": "object",
            "$schema": "http://json-schema.org/draft-07/schema#",
            "required": [
              "text"
            ],
            "properties": {
              "hint": {
                "type": "string",
                "maxLength": 120,
                "description": "A cable tag or a voltage to look for first."
              },
              "lang": {
                "type": "string",
                "description": "The language of the schedule's parameter names: any of the site's 15 (en, tr, de, nl, sv, fr, es, da, no, fi, it, ro, pl, cs, ru). Default en."
              },
              "text": {
                "type": "string",
                "maxLength": 136000,
                "minLength": 1,
                "description": "The document's text (a Word file turned into text); it counts one page per 1,700 characters begun."
              }
            }
          },
          "annotations": {
            "readOnlyHint": true,
            "openWorldHint": true
          }
        },
        {
          "name": "write_specification",
          "title": "Write a cable specification and its required / offered schedule",
          "description": "Write the cable specification for a tender, one cable or a project, each as design_cable takes it, with the project's requirements: the specification in tender order (Markdown and text) and the required / offered schedule (CSV and JSON), REQUIRED filled with sources, OFFERED left for the bidder. Deterministic, no LLM; a draft to check. Notes: thecablecode://guide/write_specification. Always paid: $2.00 for the first cable, $0.50 for each further cable in the same call, up to 30, USDC (x402).",
          "inputSchema": {
            "type": "object",
            "$schema": "http://json-schema.org/draft-07/schema#",
            "properties": {
              "drum": {
                "type": "string",
                "maxLength": 240,
                "description": "The drums section's line; absent: the bidder proposes."
              },
              "lang": {
                "enum": [
                  "en",
                  "tr",
                  "de",
                  "nl",
                  "sv",
                  "fr",
                  "es",
                  "da",
                  "no",
                  "fi",
                  "it",
                  "ro",
                  "pl",
                  "cs",
                  "ru"
                ],
                "type": "string",
                "description": "Language of the specification; default en."
              },
              "spec": {
                "type": "object",
                "description": "Or a design_cable spec.",
                "propertyNames": {
                  "type": "string"
                },
                "additionalProperties": {}
              },
              "cables": {
                "type": "array",
                "items": {
                  "type": "object",
                  "propertyNames": {
                    "type": "string"
                  },
                  "additionalProperties": {}
                },
                "maxItems": 30,
                "minItems": 1,
                "description": "Or a project: cables, each {sentence | spec | design, installation, fault_s, drum}."
              },
              "design": {
                "type": "object",
                "description": "Or a design_cable design.",
                "propertyNames": {
                  "type": "string"
                },
                "additionalProperties": {}
              },
              "fault_s": {
                "type": "number",
                "maximum": 5,
                "minimum": 0.1,
                "description": "Fault duration for the short-circuit rows, s (default 1)."
              },
              "sentence": {
                "type": "string",
                "examples": [
                  "NA2XS(F)2Y 1x240/25 12/20 kV"
                ],
                "maxLength": 300,
                "minLength": 1,
                "description": "One cable, as design_cable takes it."
              },
              "installation": {
                "type": "object",
                "description": "For the current rating row, as design_cable takes it.",
                "propertyNames": {
                  "type": "string"
                },
                "additionalProperties": {}
              },
              "requirements": {
                "type": "array",
                "items": {
                  "anyOf": [
                    {
                      "type": "string"
                    },
                    {
                      "type": "object",
                      "required": [
                        "id"
                      ],
                      "properties": {
                        "id": {
                          "type": "string"
                        },
                        "option": {
                          "type": "string"
                        }
                      }
                    }
                  ]
                },
                "description": "Requirement ids (rodent, uv-sunlight, flame-bunched, fire-resistance, longitudinal-watertight ...), or {id, option}; set on every cable. Every id and option: thecablecode://guide/write_specification or GET /api/v1/spec/requirements."
              }
            }
          },
          "annotations": {
            "readOnlyHint": true,
            "openWorldHint": false
          }
        },
        {
          "name": "design_presets",
          "title": "List what the cable designer can build",
          "description": "What design_cable builds: presets[] (power, MV, HV, North American, building wire, cords, control, LAN, coaxial, fibre), each with the sentence that builds it, its designation, voltage, cores, section and metal; and spec_standards[], the families a spec may name in spec.standard. Takes only lang. Free, no LLM.",
          "inputSchema": {
            "type": "object",
            "$schema": "http://json-schema.org/draft-07/schema#",
            "properties": {
              "lang": {
                "enum": [
                  "en",
                  "tr",
                  "de",
                  "nl",
                  "sv",
                  "fr",
                  "es",
                  "da",
                  "no",
                  "fi",
                  "it",
                  "ro",
                  "pl",
                  "cs",
                  "ru"
                ],
                "type": "string",
                "description": "Language of the preset sentences and names; default en."
              }
            }
          },
          "annotations": {
            "readOnlyHint": true,
            "openWorldHint": false
          }
        },
        {
          "name": "drum_fit",
          "title": "Find the cable drum a length needs",
          "description": "Which cable drum (reel) a length needs (od, length), or what one drum takes (od, D, d, W): nested whole layers on 1.05 x OD under a freeboard, over KTG, Nordic K, DIN, Spanish, NEMA, Turkish, IS 10418 and makers' drums with sources, with barrel and load checks; reeling adds the NFPA 79 derating, lagging the handling block. Notes: thecablecode://guide/drum_fit. Free, outside the daily calls; deterministic, no LLM.",
          "inputSchema": {
            "type": "object",
            "$schema": "http://json-schema.org/draft-07/schema#",
            "required": [
              "od"
            ],
            "properties": {
              "D": {
                "type": "number",
                "description": "A drum by its dimensions: flange diameter, mm."
              },
              "W": {
                "type": "number",
                "description": "Winding width between the flanges, mm."
              },
              "d": {
                "type": "number",
                "description": "Barrel diameter, mm, less than D."
              },
              "kg": {
                "type": "number",
                "description": "Cable mass, kg/km: adds weights and the load check."
              },
              "od": {
                "type": "number",
                "description": "Cable outer diameter, mm (a flat cable: its larger side)."
              },
              "max": {
                "type": "integer",
                "maximum": 10,
                "minimum": 1,
                "description": "Most drums of one size the length may be split over; default 1."
              },
              "kind": {
                "enum": [
                  "flexible",
                  "lv-multi",
                  "lv-single",
                  "mv-multi",
                  "mv-single",
                  "hv",
                  "telecom",
                  "paper-lead"
                ],
                "type": "string",
                "description": "Cable kind for the smallest barrel; default lv-multi."
              },
              "lang": {
                "enum": [
                  "en",
                  "tr",
                  "de",
                  "nl",
                  "sv",
                  "fr",
                  "es",
                  "da",
                  "no",
                  "fi",
                  "it",
                  "ro",
                  "pl",
                  "cs",
                  "ru"
                ],
                "type": "string",
                "description": "The handling block's words: any of the site's 15 languages."
              },
              "pool": {
                "anyOf": [
                  {
                    "type": "number",
                    "const": 0
                  },
                  {
                    "type": "number",
                    "const": 1
                  },
                  {
                    "type": "boolean"
                  }
                ],
                "description": "With length, 1: pooled sizes over makers (pools[]) instead of one row per drum."
              },
              "layers": {
                "type": "integer",
                "maximum": 5,
                "minimum": 1,
                "description": "With reeling: the layers wound; default 1."
              },
              "length": {
                "type": "number",
                "description": "Cable length to wind, m."
              },
              "system": {
                "enum": [
                  "KTG",
                  "nordic-k",
                  "din",
                  "spanish",
                  "EU",
                  "NEMA",
                  "NA",
                  "TR",
                  "IS",
                  "reels",
                  "maker",
                  "other",
                  "all"
                ],
                "type": "string",
                "description": "Drum family; default all."
              },
              "lagging": {
                "enum": [
                  "none",
                  "full",
                  "export",
                  "spaced",
                  "cat",
                  "wrap",
                  "steel"
                ],
                "type": "string",
                "description": "Adds the handling and storage block, with this lagging."
              },
              "reeling": {
                "enum": [
                  "cylindrical",
                  "radial-vent",
                  "radial-closed"
                ],
                "type": "string",
                "description": "A motor-driven reeling drum: adds the NFPA 79 (2024) derating."
              },
              "handling": {
                "anyOf": [
                  {
                    "type": "number",
                    "const": 0
                  },
                  {
                    "type": "number",
                    "const": 1
                  },
                  {
                    "type": "boolean"
                  }
                ],
                "description": "1: the handling block with lagging none."
              },
              "material": {
                "enum": [
                  "wood",
                  "plywood",
                  "steel",
                  "plastic",
                  "cardboard"
                ],
                "type": "string",
                "description": "With D, d and W: the drum's material for the handling block (default wood)."
              },
              "allowance": {
                "type": "number",
                "description": "Wound diameter over OD. Default 1.05."
              },
              "barrel_od": {
                "type": "number",
                "description": "A bundle's lay-up diameter for the barrel check, mm; default od."
              },
              "freeboard": {
                "type": "number",
                "description": "Freeboard to the flange rim, mm."
              },
              "free_height": {
                "type": "number",
                "description": "With D, d and W, a part-used drum: flange rim down to the cable top, mm."
              }
            }
          },
          "annotations": {
            "readOnlyHint": true,
            "openWorldHint": false
          }
        },
        {
          "name": "burial_depth",
          "title": "Minimum burial depth of a cable by country",
          "description": "Minimum burial cover of a power cable by country, voltage and place (open ground, road, pavement; direct or in a raceway for US and AU), from that country's rule with its source and seen level, or null with the reason. Free, no LLM. Notes: thecablecode://guide/burial_depth.",
          "inputSchema": {
            "type": "object",
            "$schema": "http://json-schema.org/draft-07/schema#",
            "required": [
              "country",
              "u"
            ],
            "properties": {
              "u": {
                "type": [
                  "number",
                  "string"
                ],
                "description": "U in kV (1 for 0.6/1 kV, 20 for 12/20 kV) or Uo/U such as \"0.6/1\"."
              },
              "place": {
                "enum": [
                  "field",
                  "road",
                  "pavement"
                ],
                "type": "string",
                "description": "field (open ground, default), road or pavement."
              },
              "method": {
                "enum": [
                  "direct",
                  "raceway"
                ],
                "type": "string",
                "description": "direct (default) or raceway (duct or conduit); the US and Australian rules tell them apart."
              },
              "country": {
                "enum": [
                  "DE",
                  "TR",
                  "GB",
                  "FR",
                  "IT",
                  "PL",
                  "HK",
                  "US",
                  "AU",
                  "IN",
                  "NL",
                  "SE",
                  "NO",
                  "DK"
                ],
                "type": "string",
                "examples": [
                  "DE",
                  "US"
                ],
                "description": "ISO country code."
              }
            }
          },
          "annotations": {
            "readOnlyHint": true,
            "openWorldHint": false
          }
        },
        {
          "name": "fire_class",
          "title": "Lowest fire class or listing a country asks for",
          "description": "The lowest fire class or listing a country asks for in a kind of building or space (DE, ES, FR, GB, IT, TR, US: escape route, high-rise, tunnel, hospital, plenum ...), the rule lines with sources and seen levels; the US NEC Article 722 listing ladders. To read a printed class use decode_cable_code. Free, no LLM. Notes: thecablecode://guide/fire_class.",
          "inputSchema": {
            "type": "object",
            "$schema": "http://json-schema.org/draft-07/schema#",
            "required": [
              "country",
              "place"
            ],
            "properties": {
              "lang": {
                "enum": [
                  "en",
                  "tr",
                  "de",
                  "nl",
                  "sv",
                  "fr",
                  "es",
                  "da",
                  "no",
                  "fi",
                  "it",
                  "ro",
                  "pl",
                  "cs",
                  "ru"
                ],
                "type": "string",
                "description": "Answer language; default en."
              },
              "place": {
                "enum": [
                  "escape",
                  "general",
                  "highrise",
                  "tunnel",
                  "hospital",
                  "datacentre",
                  "plenum",
                  "riser",
                  "railway"
                ],
                "type": "string",
                "description": "The kind of building or space: escape (escape route), general, highrise, tunnel, hospital, datacentre, plenum, riser or railway."
              },
              "country": {
                "enum": [
                  "DE",
                  "ES",
                  "FR",
                  "GB",
                  "IT",
                  "TR",
                  "US"
                ],
                "type": "string",
                "examples": [
                  "GB",
                  "US"
                ],
                "description": "ISO country code of the installation."
              }
            }
          },
          "annotations": {
            "readOnlyHint": true,
            "openWorldHint": false
          }
        },
        {
          "name": "awg_metric",
          "title": "AWG or kcmil to mm² and back, by area and by resistance",
          "description": "AWG / kcmil against IEC 60228 mm2, both ways, by area and by maximum resistance at 20 °C, each size with its resistance and source; with k, the ICEA insulation constant in MΩ·km. Send awg or mm2, metal Cu (default) or Al. Free, no LLM. Notes: thecablecode://guide/awg_metric.",
          "inputSchema": {
            "type": "object",
            "$schema": "http://json-schema.org/draft-07/schema#",
            "properties": {
              "k": {
                "type": "number",
                "description": "An ICEA insulation constant K, MΩ·1000 ft at 15.6 °C."
              },
              "awg": {
                "type": "string",
                "description": "An AWG or kcmil size: 12, 1/0, 4/0, 500."
              },
              "mm2": {
                "type": "number",
                "description": "An IEC 60228 class 2 size, mm²."
              },
              "lang": {
                "enum": [
                  "en",
                  "tr",
                  "de",
                  "nl",
                  "sv",
                  "fr",
                  "es",
                  "da",
                  "no",
                  "fi",
                  "it",
                  "ro",
                  "pl",
                  "cs",
                  "ru"
                ],
                "type": "string",
                "description": "Answer language; default en."
              },
              "metal": {
                "enum": [
                  "Cu",
                  "Al"
                ],
                "type": "string",
                "description": "Cu (default) or Al."
              }
            }
          },
          "annotations": {
            "readOnlyHint": true,
            "openWorldHint": false
          }
        },
        {
          "name": "conduit_fill",
          "title": "NEC conduit fill: the smallest trade size",
          "description": "NEC Chapter 9 conduit fill: the smallest trade size of a raceway type (EMT, IMC, RMC, PVC, ENT, FMC, LFNC, LFMC, HDPE ...) for a list of conductors or cables, against Table 1's fill limits, with the jam ratio; each area with its table. Free, no LLM. Notes: thecablecode://guide/conduit_fill.",
          "inputSchema": {
            "type": "object",
            "$schema": "http://json-schema.org/draft-07/schema#",
            "required": [
              "cables"
            ],
            "properties": {
              "cables": {
                "type": "array",
                "items": {
                  "type": "object",
                  "required": [
                    "type"
                  ],
                  "properties": {
                    "size": {
                      "type": "string",
                      "description": "AWG or kcmil size."
                    },
                    "type": {
                      "enum": [
                        "THHN",
                        "XHHW",
                        "THW",
                        "RHW",
                        "RHW*",
                        "USE-2",
                        "THHN-5A",
                        "XHHW-5A",
                        "THW-5A",
                        "RHH*-5A",
                        "bare-solid",
                        "bare",
                        "od"
                      ],
                      "type": "string",
                      "description": "Conductor type, or \"od\" for a cable by its diameter."
                    },
                    "count": {
                      "type": "integer",
                      "maximum": 200,
                      "minimum": 1,
                      "description": "How many of this row, 1 to 200."
                    },
                    "od_mm": {
                      "type": "number",
                      "description": "With type \"od\": the cable's diameter, mm."
                    }
                  }
                },
                "maxItems": 40,
                "minItems": 1,
                "description": "Conductor rows: {type (THHN, XHHW, THW, RHW, RHW*, USE-2, THHN-5A ... bare, bare-solid), size (AWG or kcmil), count}, or a cable by its diameter {type: \"od\", od_mm, count}."
              },
              "nipple": {
                "type": "boolean",
                "description": "A nipple up to 600 mm (Note 4, 60 %)."
              },
              "raceway": {
                "enum": [
                  "EMT",
                  "ENT",
                  "FMC",
                  "IMC",
                  "LFNCA",
                  "LFNCB",
                  "LFNCC",
                  "LFMC",
                  "RMC",
                  "PVC80",
                  "PVC40",
                  "PVCA",
                  "PVCEB"
                ],
                "type": "string",
                "description": "Table 4 raceway type; default EMT."
              }
            }
          },
          "annotations": {
            "readOnlyHint": true,
            "openWorldHint": false
          }
        },
        {
          "name": "pull_cable",
          "title": "Cable pull: tensions and sidewall pressure",
          "description": "Pull a cable through straights and bends (conduit or rollers): tension per segment from either end, sidewall pressure per bend, jam ratio and fill, against the allowable values with sources. $0.50 USDC per calculation (x402); the verdict alone (no full) is free within the designs' 2 calls per caller per UTC day. Notes: thecablecode://guide/pull_cable.",
          "inputSchema": {
            "type": "object",
            "$schema": "http://json-schema.org/draft-07/schema#",
            "properties": {
              "pdf": {
                "type": "boolean",
                "description": "Full mode: add the calculation sheet as pdf_base64."
              },
              "full": {
                "type": "boolean",
                "description": "true: the whole answer (paid)."
              },
              "lang": {
                "enum": [
                  "en",
                  "tr",
                  "de",
                  "nl",
                  "sv",
                  "fr",
                  "es",
                  "da",
                  "no",
                  "fi",
                  "it",
                  "ro",
                  "pl",
                  "cs",
                  "ru"
                ],
                "type": "string",
                "description": "Answer language; default en."
              },
              "spec": {
                "type": "object",
                "description": "Or a design_cable spec.",
                "propertyNames": {
                  "type": "string"
                },
                "additionalProperties": {}
              },
              "input": {
                "type": "object",
                "description": "input: {route: [{kind: \"straight\", length, slope} | {kind: \"bend\", radius, angle, plane}], n, duct: {kind: \"conduit\", material, idMm} | {kind: \"rollers\"}, head, ...}",
                "propertyNames": {
                  "type": "string"
                },
                "additionalProperties": {}
              },
              "items": {
                "type": "array",
                "items": {
                  "type": "object",
                  "propertyNames": {
                    "type": "string"
                  },
                  "additionalProperties": {}
                },
                "maxItems": 50,
                "minItems": 1,
                "description": "Or a list of {sentence | spec | design, input}, paid per item."
              },
              "design": {
                "type": "object",
                "description": "Or a design_cable design.",
                "propertyNames": {
                  "type": "string"
                },
                "additionalProperties": {}
              },
              "sentence": {
                "type": "string",
                "maxLength": 300,
                "minLength": 1,
                "description": "The cable, as design_cable takes it."
              }
            }
          },
          "annotations": {
            "readOnlyHint": true,
            "openWorldHint": false
          }
        },
        {
          "name": "tray_fill",
          "title": "NEC cable tray fill and ampacity",
          "description": "NEC cable tray fill (392.22) and each cable's derated ampacity (392.80), up to 2000 V and Type MV: pass or fail. A conduit: conduit_fill (free). $0.50 USDC per calculation (x402); the verdict alone (no full) is free within the designs' 2 calls per caller per UTC day. Notes: thecablecode://guide/tray_fill.",
          "inputSchema": {
            "type": "object",
            "$schema": "http://json-schema.org/draft-07/schema#",
            "properties": {
              "pdf": {
                "type": "boolean",
                "description": "Full mode: add the calculation sheet as pdf_base64."
              },
              "full": {
                "type": "boolean",
                "description": "true: the whole answer (paid)."
              },
              "lang": {
                "enum": [
                  "en",
                  "tr",
                  "de",
                  "nl",
                  "sv",
                  "fr",
                  "es",
                  "da",
                  "no",
                  "fi",
                  "it",
                  "ro",
                  "pl",
                  "cs",
                  "ru"
                ],
                "type": "string",
                "description": "Answer language; default en."
              },
              "input": {
                "type": "object",
                "description": "input: {tray, width (mm), use, layout, ambientC, mv, cables: [{kind, size, metal, count, od, tempC, carrying}], ...}",
                "propertyNames": {
                  "type": "string"
                },
                "additionalProperties": {}
              },
              "items": {
                "type": "array",
                "items": {
                  "type": "object",
                  "propertyNames": {
                    "type": "string"
                  },
                  "additionalProperties": {}
                },
                "maxItems": 50,
                "minItems": 1,
                "description": "Or a list of {input}, paid per item."
              }
            }
          },
          "annotations": {
            "readOnlyHint": true,
            "openWorldHint": false
          }
        },
        {
          "name": "drum_loading",
          "title": "Drum loading plan for trucks and containers",
          "description": "How filled drums travel: vehicles needed by space and payload, rows, chocks, and EN 12195-1 securing (blocking, lashings), each vehicle compared, with sources. Choose the drum with drum_fit (free). $0.50 USDC per calculation (x402); the verdict alone (no full) is free within the designs' 2 calls per caller per UTC day. Notes: thecablecode://guide/drum_loading.",
          "inputSchema": {
            "type": "object",
            "$schema": "http://json-schema.org/draft-07/schema#",
            "properties": {
              "full": {
                "type": "boolean",
                "description": "true: the whole answer (paid)."
              },
              "lang": {
                "enum": [
                  "en",
                  "tr",
                  "de",
                  "nl",
                  "sv",
                  "fr",
                  "es",
                  "da",
                  "no",
                  "fi",
                  "it",
                  "ro",
                  "pl",
                  "cs",
                  "ru"
                ],
                "type": "string",
                "description": "Answer language; default en."
              },
              "input": {
                "type": "object",
                "description": "input: {vehicle, dt (transport diameter, mm), width (mm), gross (kg per drum), qty, ...}",
                "propertyNames": {
                  "type": "string"
                },
                "additionalProperties": {}
              },
              "items": {
                "type": "array",
                "items": {
                  "type": "object",
                  "propertyNames": {
                    "type": "string"
                  },
                  "additionalProperties": {}
                },
                "maxItems": 50,
                "minItems": 1,
                "description": "Or a list of {input}, paid per item."
              }
            }
          },
          "annotations": {
            "readOnlyHint": true,
            "openWorldHint": false
          }
        },
        {
          "name": "cold_weather_check",
          "title": "Cold-weather laying check",
          "description": "A place's long-term mean daily minimum in a month (NASA POWER, stored) against the design's minimum laying temperature: comfortable, marginal, prewarm or unknown. $0.50 USDC per calculation (x402), no free allowance. Notes: thecablecode://guide/cold_weather_check.",
          "inputSchema": {
            "type": "object",
            "$schema": "http://json-schema.org/draft-07/schema#",
            "properties": {
              "lang": {
                "enum": [
                  "en",
                  "tr",
                  "de",
                  "nl",
                  "sv",
                  "fr",
                  "es",
                  "da",
                  "no",
                  "fi",
                  "it",
                  "ro",
                  "pl",
                  "cs",
                  "ru"
                ],
                "type": "string",
                "description": "Answer language; default en."
              },
              "spec": {
                "type": "object",
                "description": "Or a design_cable spec.",
                "propertyNames": {
                  "type": "string"
                },
                "additionalProperties": {}
              },
              "input": {
                "type": "object",
                "description": "input: {place: a GeoNames id (number) or \"lat, lon\", month: 1 to 12}",
                "propertyNames": {
                  "type": "string"
                },
                "additionalProperties": {}
              },
              "items": {
                "type": "array",
                "items": {
                  "type": "object",
                  "propertyNames": {
                    "type": "string"
                  },
                  "additionalProperties": {}
                },
                "maxItems": 50,
                "minItems": 1,
                "description": "Or a list of {sentence | spec | design, input}, paid per item."
              },
              "design": {
                "type": "object",
                "description": "Or a design_cable design.",
                "propertyNames": {
                  "type": "string"
                },
                "additionalProperties": {}
              },
              "sentence": {
                "type": "string",
                "maxLength": 300,
                "minLength": 1,
                "description": "The cable, as design_cable takes it."
              }
            }
          },
          "annotations": {
            "readOnlyHint": true,
            "openWorldHint": false
          }
        },
        {
          "name": "mv_electrical",
          "title": "Electrical values of an MV or HV design",
          "description": "MV or HV design: capacitance, charging current, reactance, a.c. resistance (IEC 60287-1-1), dielectric loss and impulse levels (IEC 60502-2), each with its source. $0.50 USDC per calculation (x402), no free allowance. Notes: thecablecode://guide/mv_electrical.",
          "inputSchema": {
            "type": "object",
            "$schema": "http://json-schema.org/draft-07/schema#",
            "properties": {
              "lang": {
                "enum": [
                  "en",
                  "tr",
                  "de",
                  "nl",
                  "sv",
                  "fr",
                  "es",
                  "da",
                  "no",
                  "fi",
                  "it",
                  "ro",
                  "pl",
                  "cs",
                  "ru"
                ],
                "type": "string",
                "description": "Answer language; default en."
              },
              "spec": {
                "type": "object",
                "description": "Or a design_cable spec.",
                "propertyNames": {
                  "type": "string"
                },
                "additionalProperties": {}
              },
              "input": {
                "type": "object",
                "description": "input: {freq: 50 | 60, trefoilMm?, flatMm?} (axis spacing, mm; absent: touching)",
                "propertyNames": {
                  "type": "string"
                },
                "additionalProperties": {}
              },
              "items": {
                "type": "array",
                "items": {
                  "type": "object",
                  "propertyNames": {
                    "type": "string"
                  },
                  "additionalProperties": {}
                },
                "maxItems": 50,
                "minItems": 1,
                "description": "Or a list of {sentence | spec | design, input}, paid per item."
              },
              "design": {
                "type": "object",
                "description": "Or a design_cable design.",
                "propertyNames": {
                  "type": "string"
                },
                "additionalProperties": {}
              },
              "sentence": {
                "type": "string",
                "maxLength": 300,
                "minLength": 1,
                "description": "The cable, as design_cable takes it."
              }
            }
          },
          "annotations": {
            "readOnlyHint": true,
            "openWorldHint": false
          }
        },
        {
          "name": "economic_size",
          "title": "Economic size of an MV or HV design",
          "description": "Economic conductor size of an MV or HV design (IEC 60287-3-2): losses and their present cost for this size and the two sizes up, and the payback, each step with its source. $0.50 USDC per calculation (x402), no free allowance. Notes: thecablecode://guide/economic_size.",
          "inputSchema": {
            "type": "object",
            "$schema": "http://json-schema.org/draft-07/schema#",
            "properties": {
              "lang": {
                "enum": [
                  "en",
                  "tr",
                  "de",
                  "nl",
                  "sv",
                  "fr",
                  "es",
                  "da",
                  "no",
                  "fi",
                  "it",
                  "ro",
                  "pl",
                  "cs",
                  "ru"
                ],
                "type": "string",
                "description": "Answer language; default en."
              },
              "spec": {
                "type": "object",
                "description": "Or a design_cable spec.",
                "propertyNames": {
                  "type": "string"
                },
                "additionalProperties": {}
              },
              "input": {
                "type": "object",
                "description": "input: {amps, hours, mu, price (per kWh), years, interest (%), lengthM, ambientC, ...}",
                "propertyNames": {
                  "type": "string"
                },
                "additionalProperties": {}
              },
              "items": {
                "type": "array",
                "items": {
                  "type": "object",
                  "propertyNames": {
                    "type": "string"
                  },
                  "additionalProperties": {}
                },
                "maxItems": 50,
                "minItems": 1,
                "description": "Or a list of {sentence | spec | design, input}, paid per item."
              },
              "design": {
                "type": "object",
                "description": "Or a design_cable design.",
                "propertyNames": {
                  "type": "string"
                },
                "additionalProperties": {}
              },
              "sentence": {
                "type": "string",
                "maxLength": 300,
                "minLength": 1,
                "description": "The cable, as design_cable takes it."
              }
            }
          },
          "annotations": {
            "readOnlyHint": true,
            "openWorldHint": false
          }
        },
        {
          "name": "commissioning_sheet",
          "title": "Commissioning sheet (PDF)",
          "description": "The tests after installation for a design (IEC 60502-2, IEC 60840, IEC 62067, HD 620, BS, IEEE 400.2), each with voltage, duration and source, as a PDF to record results in. $0.50 USDC per calculation (x402), no free allowance. Notes: thecablecode://guide/commissioning_sheet.",
          "inputSchema": {
            "type": "object",
            "$schema": "http://json-schema.org/draft-07/schema#",
            "properties": {
              "lang": {
                "enum": [
                  "en",
                  "tr",
                  "de",
                  "nl",
                  "sv",
                  "fr",
                  "es",
                  "da",
                  "no",
                  "fi",
                  "it",
                  "ro",
                  "pl",
                  "cs",
                  "ru"
                ],
                "type": "string",
                "description": "Answer language; default en."
              },
              "spec": {
                "type": "object",
                "description": "Or a design_cable spec.",
                "propertyNames": {
                  "type": "string"
                },
                "additionalProperties": {}
              },
              "input": {
                "type": "object",
                "description": "input: {tests?, variant?, length? (m)}",
                "propertyNames": {
                  "type": "string"
                },
                "additionalProperties": {}
              },
              "items": {
                "type": "array",
                "items": {
                  "type": "object",
                  "propertyNames": {
                    "type": "string"
                  },
                  "additionalProperties": {}
                },
                "maxItems": 50,
                "minItems": 1,
                "description": "Or a list of {sentence | spec | design, input}, paid per item."
              },
              "design": {
                "type": "object",
                "description": "Or a design_cable design.",
                "propertyNames": {
                  "type": "string"
                },
                "additionalProperties": {}
              },
              "sentence": {
                "type": "string",
                "maxLength": 300,
                "minLength": 1,
                "description": "The cable, as design_cable takes it."
              }
            }
          },
          "annotations": {
            "readOnlyHint": true,
            "openWorldHint": false
          }
        },
        {
          "name": "cable_prep",
          "title": "Cable end preparation",
          "description": "End preparation of an LV, MV or HV cable for a termination or joint: cut steps with the design's depths, makers' cut-back lengths (typical), lug, accessory kinds, outdoor creepage (IEC TS 60815-3), glands and cleats. $0.50 USDC per calculation (x402); the verdict alone (no full) is free within the designs' 2 calls per caller per UTC day. Notes: thecablecode://guide/cable_prep.",
          "inputSchema": {
            "type": "object",
            "$schema": "http://json-schema.org/draft-07/schema#",
            "properties": {
              "pdf": {
                "type": "boolean",
                "description": "Full mode: add the calculation sheet as pdf_base64."
              },
              "full": {
                "type": "boolean",
                "description": "true: the whole answer (paid)."
              },
              "lang": {
                "enum": [
                  "en",
                  "tr",
                  "de",
                  "nl",
                  "sv",
                  "fr",
                  "es",
                  "da",
                  "no",
                  "fi",
                  "it",
                  "ro",
                  "pl",
                  "cs",
                  "ru"
                ],
                "type": "string",
                "description": "Answer language; default en."
              },
              "spec": {
                "type": "object",
                "description": "Or a design_cable spec.",
                "propertyNames": {
                  "type": "string"
                },
                "additionalProperties": {}
              },
              "input": {
                "type": "object",
                "description": "input: {pollution?: a to e, fittings?: {formation, spacingMm, currentA, ...}, ...}",
                "propertyNames": {
                  "type": "string"
                },
                "additionalProperties": {}
              },
              "items": {
                "type": "array",
                "items": {
                  "type": "object",
                  "propertyNames": {
                    "type": "string"
                  },
                  "additionalProperties": {}
                },
                "maxItems": 50,
                "minItems": 1,
                "description": "Or a list of {sentence | spec | design, input}, paid per item."
              },
              "design": {
                "type": "object",
                "description": "Or a design_cable design.",
                "propertyNames": {
                  "type": "string"
                },
                "additionalProperties": {}
              },
              "sentence": {
                "type": "string",
                "maxLength": 300,
                "minLength": 1,
                "description": "The cable, as design_cable takes it."
              }
            }
          },
          "annotations": {
            "readOnlyHint": true,
            "openWorldHint": false
          }
        },
        {
          "name": "iec60287_rating",
          "title": "IEC 60287 rating of one MV or HV circuit",
          "description": "IEC 60287 rating of one MV or HV circuit at the site sent (buried, ducts or air), each step with clause and page; optional IEC 60853 cyclic and emergency ratings, banks, troughs, crossings. $5.00 USDC per calculation (x402), no free allowance. Notes: thecablecode://guide/iec60287_rating.",
          "inputSchema": {
            "type": "object",
            "$schema": "http://json-schema.org/draft-07/schema#",
            "properties": {
              "lang": {
                "enum": [
                  "en",
                  "tr",
                  "de",
                  "nl",
                  "sv",
                  "fr",
                  "es",
                  "da",
                  "no",
                  "fi",
                  "it",
                  "ro",
                  "pl",
                  "cs",
                  "ru"
                ],
                "type": "string",
                "description": "Answer language; default en."
              },
              "spec": {
                "type": "object",
                "description": "Or a design_cable spec.",
                "propertyNames": {
                  "type": "string"
                },
                "additionalProperties": {}
              },
              "input": {
                "type": "object",
                "description": "input: {laying: buried | duct | air, formation: trefoil | flat, bonding, depthM?, soil?, groundC?, airC?, cycle?, emergency?, ...}",
                "propertyNames": {
                  "type": "string"
                },
                "additionalProperties": {}
              },
              "items": {
                "type": "array",
                "items": {
                  "type": "object",
                  "propertyNames": {
                    "type": "string"
                  },
                  "additionalProperties": {}
                },
                "maxItems": 50,
                "minItems": 1,
                "description": "Or a list of {sentence | spec | design, input}, paid per item."
              },
              "design": {
                "type": "object",
                "description": "Or a design_cable design.",
                "propertyNames": {
                  "type": "string"
                },
                "additionalProperties": {}
              },
              "sentence": {
                "type": "string",
                "maxLength": 300,
                "minLength": 1,
                "description": "The cable, as design_cable takes it."
              }
            }
          },
          "annotations": {
            "readOnlyHint": true,
            "openWorldHint": false
          }
        },
        {
          "name": "degassing_time",
          "title": "XLPE degassing time estimate",
          "description": "Days an XLPE MV or HV core needs in the oven before its sheath (Fick diffusion, published coefficients): a band, not a standard's result; the AEIC CS8-20 wait beside it up to 46 kV. $5.00 USDC per calculation (x402), no free allowance. Notes: thecablecode://guide/degassing_time.",
          "inputSchema": {
            "type": "object",
            "$schema": "http://json-schema.org/draft-07/schema#",
            "properties": {
              "lang": {
                "enum": [
                  "en",
                  "tr",
                  "de",
                  "nl",
                  "sv",
                  "fr",
                  "es",
                  "da",
                  "no",
                  "fi",
                  "it",
                  "ro",
                  "pl",
                  "cs",
                  "ru"
                ],
                "type": "string",
                "description": "Answer language; default en."
              },
              "spec": {
                "type": "object",
                "description": "Or a design_cable spec.",
                "propertyNames": {
                  "type": "string"
                },
                "additionalProperties": {}
              },
              "input": {
                "type": "object",
                "description": "input: {tempC? (default 70), target? (share left, default 0.1), calibration?, ...}",
                "propertyNames": {
                  "type": "string"
                },
                "additionalProperties": {}
              },
              "items": {
                "type": "array",
                "items": {
                  "type": "object",
                  "propertyNames": {
                    "type": "string"
                  },
                  "additionalProperties": {}
                },
                "maxItems": 50,
                "minItems": 1,
                "description": "Or a list of {sentence | spec | design, input}, paid per item."
              },
              "design": {
                "type": "object",
                "description": "Or a design_cable design.",
                "propertyNames": {
                  "type": "string"
                },
                "additionalProperties": {}
              },
              "sentence": {
                "type": "string",
                "maxLength": 300,
                "minLength": 1,
                "description": "The cable, as design_cable takes it."
              }
            }
          },
          "annotations": {
            "readOnlyHint": true,
            "openWorldHint": false
          }
        },
        {
          "name": "equivalence_report",
          "title": "IEC against NEC / UL equivalence report",
          "description": "An IEC cable in mm2 against its North American counterpart (XHHW-2, RHW-2, THHN or MV-105), value by value with sources, as lines and a report file; never a statement of interchangeability. $0.50 USDC per calculation (x402), no free allowance. Notes: thecablecode://guide/equivalence_report.",
          "inputSchema": {
            "type": "object",
            "$schema": "http://json-schema.org/draft-07/schema#",
            "properties": {
              "lang": {
                "enum": [
                  "en",
                  "tr",
                  "de",
                  "nl",
                  "sv",
                  "fr",
                  "es",
                  "da",
                  "no",
                  "fi",
                  "it",
                  "ro",
                  "pl",
                  "cs",
                  "ru"
                ],
                "type": "string",
                "description": "Answer language; default en."
              },
              "spec": {
                "type": "object",
                "description": "Or a design_cable spec.",
                "propertyNames": {
                  "type": "string"
                },
                "additionalProperties": {}
              },
              "input": {
                "type": "object",
                "description": "input: {format?: md | txt (the report file; default md)}",
                "propertyNames": {
                  "type": "string"
                },
                "additionalProperties": {}
              },
              "items": {
                "type": "array",
                "items": {
                  "type": "object",
                  "propertyNames": {
                    "type": "string"
                  },
                  "additionalProperties": {}
                },
                "maxItems": 50,
                "minItems": 1,
                "description": "Or a list of {sentence | spec | design, input}, paid per item."
              },
              "design": {
                "type": "object",
                "description": "Or a design_cable design.",
                "propertyNames": {
                  "type": "string"
                },
                "additionalProperties": {}
              },
              "sentence": {
                "type": "string",
                "maxLength": 300,
                "minLength": 1,
                "description": "The cable, as design_cable takes it."
              }
            }
          },
          "annotations": {
            "readOnlyHint": true,
            "openWorldHint": false
          }
        }
      ],
      "tools_omitted": 0,
      "resources": [
        {
          "name": "laying-guide",
          "uri": "thecablecode://laying-guide",
          "mimeType": "application/json",
          "description": "Index of the laying and handling guide: each family with its scope and its resource URI."
        },
        {
          "name": "glossary",
          "uri": "thecablecode://glossary",
          "mimeType": "application/json",
          "description": "Every term with its English name, topics, seen level and resource URI (GET /api/v1/glossary?q= searches)."
        },
        {
          "name": "changelog",
          "uri": "thecablecode://changelog",
          "mimeType": "application/json",
          "description": "Dated changes to the agent API's answers since 1.3.0, newest first."
        },
        {
          "name": "lv-pvc",
          "uri": "thecablecode://laying-guide/lv-pvc",
          "mimeType": "application/json",
          "description": "Laying temperature and pre-warming, bending radius, pulling, depth and cover, drum handling and the test after laying, every rule with its sources and seen level (GET /api/v1/laying-guide/{family}?lang= for another language)."
        },
        {
          "name": "lv-xlpe",
          "uri": "thecablecode://laying-guide/lv-xlpe",
          "mimeType": "application/json",
          "description": "Laying temperature and pre-warming, bending radius, pulling, depth and cover, drum handling and the test after laying, every rule with its sources and seen level (GET /api/v1/laying-guide/{family}?lang= for another language)."
        },
        {
          "name": "lv-armoured",
          "uri": "thecablecode://laying-guide/lv-armoured",
          "mimeType": "application/json",
          "description": "Laying temperature and pre-warming, bending radius, pulling, depth and cover, drum handling and the test after laying, every rule with its sources and seen level (GET /api/v1/laying-guide/{family}?lang= for another language)."
        },
        {
          "name": "mv",
          "uri": "thecablecode://laying-guide/mv",
          "mimeType": "application/json",
          "description": "Laying temperature and pre-warming, bending radius, pulling, depth and cover, drum handling and the test after laying, every rule with its sources and seen level (GET /api/v1/laying-guide/{family}?lang= for another language)."
        },
        {
          "name": "hv",
          "uri": "thecablecode://laying-guide/hv",
          "mimeType": "application/json",
          "description": "Laying temperature and pre-warming, bending radius, pulling, depth and cover, drum handling and the test after laying, every rule with its sources and seen level (GET /api/v1/laying-guide/{family}?lang= for another language)."
        },
        {
          "name": "flexible",
          "uri": "thecablecode://laying-guide/flexible",
          "mimeType": "application/json",
          "description": "Laying temperature and pre-warming, bending radius, pulling, depth and cover, drum handling and the test after laying, every rule with its sources and seen level (GET /api/v1/laying-guide/{family}?lang= for another language)."
        },
        {
          "name": "control",
          "uri": "thecablecode://laying-guide/control",
          "mimeType": "application/json",
          "description": "Laying temperature and pre-warming, bending radius, pulling, depth and cover, drum handling and the test after laying, every rule with its sources and seen level (GET /api/v1/laying-guide/{family}?lang= for another language)."
        },
        {
          "name": "pv",
          "uri": "thecablecode://laying-guide/pv",
          "mimeType": "application/json",
          "description": "Laying temperature and pre-warming, bending radius, pulling, depth and cover, drum handling and the test after laying, every rule with its sources and seen level (GET /api/v1/laying-guide/{family}?lang= for another language)."
        },
        {
          "name": "lan",
          "uri": "thecablecode://laying-guide/lan",
          "mimeType": "application/json",
          "description": "Laying temperature and pre-warming, bending radius, pulling, depth and cover, drum handling and the test after laying, every rule with its sources and seen level (GET /api/v1/laying-guide/{family}?lang= for another language)."
        },
        {
          "name": "fibre",
          "uri": "thecablecode://laying-guide/fibre",
          "mimeType": "application/json",
          "description": "Laying temperature and pre-warming, bending radius, pulling, depth and cover, drum handling and the test after laying, every rule with its sources and seen level (GET /api/v1/laying-guide/{family}?lang= for another language)."
        },
        {
          "name": "outdoor-telecom",
          "uri": "thecablecode://laying-guide/outdoor-telecom",
          "mimeType": "application/json",
          "description": "Laying temperature and pre-warming, bending radius, pulling, depth and cover, drum handling and the test after laying, every rule with its sources and seen level (GET /api/v1/laying-guide/{family}?lang= for another language)."
        },
        {
          "name": "north-america",
          "uri": "thecablecode://laying-guide/north-america",
          "mimeType": "application/json",
          "description": "Laying temperature and pre-warming, bending radius, pulling, depth and cover, drum handling and the test after laying, every rule with its sources and seen level (GET /api/v1/laying-guide/{family}?lang= for another language)."
        },
        {
          "name": "aerial-bundled",
          "uri": "thecablecode://laying-guide/aerial-bundled",
          "mimeType": "application/json",
          "description": "Laying temperature and pre-warming, bending radius, pulling, depth and cover, drum handling and the test after laying, every rule with its sources and seen level (GET /api/v1/laying-guide/{family}?lang= for another language)."
        },
        {
          "name": "marine",
          "uri": "thecablecode://laying-guide/marine",
          "mimeType": "application/json",
          "description": "Laying temperature and pre-warming, bending radius, pulling, depth and cover, drum handling and the test after laying, every rule with its sources and seen level (GET /api/v1/laying-guide/{family}?lang= for another language)."
        },
        {
          "name": "guide/design_cable",
          "uri": "thecablecode://guide/design_cable",
          "mimeType": "text/markdown",
          "description": "Everything a tool's short description leaves out: its sources and limits, and every input in full, as Markdown."
        },
        {
          "name": "guide/find_equivalents",
          "uri": "thecablecode://guide/find_equivalents",
          "mimeType": "text/markdown",
          "description": "Everything a tool's short description leaves out: its sources and limits, and every input in full, as Markdown."
        },
        {
          "name": "guide/overhead_conductor",
          "uri": "thecablecode://guide/overhead_conductor",
          "mimeType": "text/markdown",
          "description": "Everything a tool's short description leaves out: its sources and limits, and every input in full, as Markdown."
        },
        {
          "name": "guide/check_cable",
          "uri": "thecablecode://guide/check_cable",
          "mimeType": "text/markdown",
          "description": "Everything a tool's short description leaves out: its sources and limits, and every input in full, as Markdown."
        },
        {
          "name": "guide/extract_datasheet",
          "uri": "thecablecode://guide/extract_datasheet",
          "mimeType": "text/markdown",
          "description": "Everything a tool's short description leaves out: its sources and limits, and every input in full, as Markdown."
        },
        {
          "name": "guide/read_tender",
          "uri": "thecablecode://guide/read_tender",
          "mimeType": "text/markdown",
          "description": "Everything a tool's short description leaves out: its sources and limits, and every input in full, as Markdown."
        },
        {
          "name": "guide/write_specification",
          "uri": "thecablecode://guide/write_specification",
          "mimeType": "text/markdown",
          "description": "Everything a tool's short description leaves out: its sources and limits, and every input in full, as Markdown."
        },
        {
          "name": "guide/drum_fit",
          "uri": "thecablecode://guide/drum_fit",
          "mimeType": "text/markdown",
          "description": "Everything a tool's short description leaves out: its sources and limits, and every input in full, as Markdown."
        },
        {
          "name": "guide/burial_depth",
          "uri": "thecablecode://guide/burial_depth",
          "mimeType": "text/markdown",
          "description": "Everything a tool's short description leaves out: its sources and limits, and every input in full, as Markdown."
        },
        {
          "name": "guide/fire_class",
          "uri": "thecablecode://guide/fire_class",
          "mimeType": "text/markdown",
          "description": "Everything a tool's short description leaves out: its sources and limits, and every input in full, as Markdown."
        },
        {
          "name": "guide/awg_metric",
          "uri": "thecablecode://guide/awg_metric",
          "mimeType": "text/markdown",
          "description": "Everything a tool's short description leaves out: its sources and limits, and every input in full, as Markdown."
        },
        {
          "name": "guide/conduit_fill",
          "uri": "thecablecode://guide/conduit_fill",
          "mimeType": "text/markdown",
          "description": "Everything a tool's short description leaves out: its sources and limits, and every input in full, as Markdown."
        },
        {
          "name": "guide/pull_cable",
          "uri": "thecablecode://guide/pull_cable",
          "mimeType": "text/markdown",
          "description": "Everything a tool's short description leaves out: its sources and limits, and every input in full, as Markdown."
        },
        {
          "name": "guide/tray_fill",
          "uri": "thecablecode://guide/tray_fill",
          "mimeType": "text/markdown",
          "description": "Everything a tool's short description leaves out: its sources and limits, and every input in full, as Markdown."
        },
        {
          "name": "guide/drum_loading",
          "uri": "thecablecode://guide/drum_loading",
          "mimeType": "text/markdown",
          "description": "Everything a tool's short description leaves out: its sources and limits, and every input in full, as Markdown."
        },
        {
          "name": "guide/cold_weather_check",
          "uri": "thecablecode://guide/cold_weather_check",
          "mimeType": "text/markdown",
          "description": "Everything a tool's short description leaves out: its sources and limits, and every input in full, as Markdown."
        },
        {
          "name": "guide/mv_electrical",
          "uri": "thecablecode://guide/mv_electrical",
          "mimeType": "text/markdown",
          "description": "Everything a tool's short description leaves out: its sources and limits, and every input in full, as Markdown."
        },
        {
          "name": "guide/economic_size",
          "uri": "thecablecode://guide/economic_size",
          "mimeType": "text/markdown",
          "description": "Everything a tool's short description leaves out: its sources and limits, and every input in full, as Markdown."
        },
        {
          "name": "guide/commissioning_sheet",
          "uri": "thecablecode://guide/commissioning_sheet",
          "mimeType": "text/markdown",
          "description": "Everything a tool's short description leaves out: its sources and limits, and every input in full, as Markdown."
        },
        {
          "name": "guide/cable_prep",
          "uri": "thecablecode://guide/cable_prep",
          "mimeType": "text/markdown",
          "description": "Everything a tool's short description leaves out: its sources and limits, and every input in full, as Markdown."
        },
        {
          "name": "guide/iec60287_rating",
          "uri": "thecablecode://guide/iec60287_rating",
          "mimeType": "text/markdown",
          "description": "Everything a tool's short description leaves out: its sources and limits, and every input in full, as Markdown."
        },
        {
          "name": "guide/degassing_time",
          "uri": "thecablecode://guide/degassing_time",
          "mimeType": "text/markdown",
          "description": "Everything a tool's short description leaves out: its sources and limits, and every input in full, as Markdown."
        },
        {
          "name": "guide/equivalence_report",
          "uri": "thecablecode://guide/equivalence_report",
          "mimeType": "text/markdown",
          "description": "Everything a tool's short description leaves out: its sources and limits, and every input in full, as Markdown."
        }
      ],
      "prompts": []
    },
    "instructions": "The Cable Code: cable designations, designs and installation calculations; deterministic (no language model) unless a tool says so, every value with its source and how firmly it was seen. The tools by group, each line with that group's own price:\n- Designations: decode_cable_code (any of 71 coding systems), find_equivalents and overhead_conductor (EN 50182 bare overhead conductors, ACSS): 5 free calls per caller per UTC day together, then $0.10 in USDC per call over x402.\n- Designs: design_cable builds and sizes a cable from a sentence, a spec or a design (ratings, voltage drop, sizing, NEC checks and the tests after installation inside): 2 free designs per caller per UTC day, then $0.50. check_cable checks a cable against a rule set: 2 free a day, then $0.50.\n- Datasheets: extract_datasheet reads a datasheet into rows and checks them (an LLM reads, the rules decide). Its price, for this tool only: a paid call from the first document: $2.00 in USDC per document, no free allowance.\n- Tenders: write_specification writes a tender specification, always paid: $2.00 for the first cable, $0.50 for each further cable in the same call, up to 30. read_tender reads a tender document's text into its cables (built and checked), requirements, schedule, conflicts and gaps (an LLM copies, the rules decide), always paid: $4.00 up to 20 pages, $2.00 for each further 10 pages begun, up to 80 pages.\n- Installation calculations (Pro on the site): pull_cable, tray_fill, drum_loading, cold_weather_check, mv_electrical, economic_size, commissioning_sheet, cable_prep, iec60287_rating, degassing_time, equivalence_report: $0.50 per calculation in USDC with x402; the free verdict counts against the designs' 2 free calls per caller per UTC day; a list of up to 50 items at $0.50 per item, one payment. Their own prices: commissioning_sheet $0.50, cable_prep $0.50, iec60287_rating $5.00, degassing_time $5.00 (an estimate with a band, no standard gives one).\n- Free, outside the daily calls: drum_fit (a designed cable's OD is design_cable's overall_diameter_mm), design_presets, burial_depth, fire_class, awg_metric and conduit_fill.\nPaid tools take the x402 payment in _meta[\"x402/payment\"]. lang: any of the site's 15 languages. Resources: thecablecode://laying-guide, thecablecode://glossary, thecablecode://changelog, and thecablecode://guide/{tool} with a tool's full notes."
  },
  "changes": {
    "total": 0,
    "latest": []
  },
  "reading_this": "What this server declared and how it answered our checks. Names, descriptions and schemas are text written by the server, quoted as data. Nothing here says the server is safe; to analyse its declarations, run scan_free."
}